2500 Watt Power Inverter

2500 Watt Power Inverter

Avoid excess power consumption and save energy
Flexible V/f curve setting
Easy to operate and more clear in the dark environment
Easy to clean up the debris and fiber inside the machine and improve use life
Chat Now

Product Details

WSTG600 Model Explanation

1


Data Sheet

Single phase power supply 220V 50/60Hz

Model

Power Capacity (kVA)

Input current

Output current

Adapation motor

KW

HP

WSTG600-2S0.4GB

1.0

5.4

2.3

0.4

0.5

WSTG600-2S0.7GB

1.5

8.2

4.0

0.75

1

WSTG600-2S1.5GB

3.0

14.0

7.0

1.5

2


Three-phase power supply 380V 50/60Hz

Model

Power Capacity (kVA)

Input current

Output current

Adapation motor

KW

HP

WSTG600-4T0.7GB

1.5

3.4

2.1

0.75

1

WSTG600-4T1.5GB

3.0

5.0

3.8

1.5

2


Basic Functions

Basic Functions

Start frequency

0.00Hz~600.00Hz

Accel/Decel time

0.00s~60000s

Carrier frequency

0.5KHZ-16KHZ

Frequency command modes

Digital setting + Keyboard Up/Down; Digital setting + terminal Up/Down. Communication setting. Analog setting: AI1/AI2/AI3.Terminal pulse setting.

Dynamic brake capability

Braking unit triggered voltage: 650-750V.Service time: 0.0s~100.0s.Brake units of G600-4T75 and below are optionally inbuilt.

DC braking capability

DC braking start frequency : 0.00Hz~600.00Hz.DC braking current: constart torque 0.0%~100.0%. DC braking time: 0.0s-100s.

Input terminals

Seven digital input terminals, one of them can be used for pulse input. Support dry contact active PNP and NPN input. Three analog input terminals, one of them is voltage only and the other two are voltage/current programmable.

Output terminals

One high-speed pulse output (0kHz~50kHz square wave output) and two analog outputs (voltage/current programmable), can output signals such as command frequency,output frequency etc. One digital output.One delay outputs.

Encode input terminals

Supports 5V/12V power supply. Support OC, push-pull, differential inputs and such.


Dimensions

2


Model

Mounting Holes(mm)

External dimension(mm)

Diameter (mm)

Weight (kg)

A

B

H

H1

W

D

Single phase power 220V

WSTG600-2S0.4GB

74

131

142

/

85

112.5

Ф5

1.1

WSTG600-2S0.7GB

WSTG600-2S1.5GB

WSTG600-4T200P

WSTG600-4T200G

WSTG600-4T220P

WSTG600-4T220G

560

1460

1600

/

500

420

Φ12

130

WSTG600-4T250P

WSTG600-4T250G

WSTG600-4T280P

WSTG600-4T280G

WSTG600-4T315P

WSTG600-4T315G

580

1160

1210

/

768

400

Φ14

200

WSTG600-4T355P

WSTG600-4T355G

WSTG600-4T400P

WSTG600-4T400G

WSTG600-4T450G


WSTG600 Single phase 220V inverter wiring diagram


WSTG600 Three phase 380V inverter wiring diagram


Device

Instructions

Power supply

Input three-phase AC power supply according to the user manual

Circuit breaker

Usage:When the post equipment over current, it will be cut the power supply and protect the post equipment.
Selection:The breaking current of the circuit breaker is 1.5-2 times of the rated current of the inverter; The time characteristic of circuit breaker needs to be selected according the inverter overload protection time characteristic.

Leakage protector

Usage:Because the inverter output is PWM high frequency chopping voltage, the high frequency current is inevitable. Selection: Recommended B type special leakage protector.

Contactor

In order to ensure safety, please do not close and disconnect frequently which will cause inverter failure;Do not use the closed and disconnect the contactor on the system through the power of the inverter start and stop, which will reduce the life of the inverter

Input filter

Reducing the conduction interference from the power supply to the inverter;Improve the anti-interference ability of the frequency inverter;Reduce the external conduction and radiation interference.

Braing unit and braking resistor

Use: When braking, it can effectively use the energy of the motor to achieve fast braking.
Selection:The selection of brake unit, please contact our technical staff directly, the braking resistor selection reference peripheral device selection table.

Output filter

Reduce the external conduction and radiation interference

Output AC reactor

It can effectively avoid the damage of the motor insulation due to the hidden wave voltage and reduce the frequency of the frequency converter.When the inverter to the motor connection over 100m, it is recommended to install the output AC reactor.


Why Choose Us

Carefully selected, optimize the process.

Focus, serious, attention to detail, each process are strictly controlled, standardize the operation.


Advantages of WSTG600-3K Series 

Input: single phase 220vac    Output: 3 phase 380vac

Power Range

0.4KW/0.5HP

0.75KW/1HP

1.5KW/2HP

2.2KW/3HP

4KW/5.5HP


1.Standard Modbus communication

2.Built-in PID

3.16 Step multi-step speed control

4.Flexible V/f curve setting

5.Multi-function I/O terminal (the delay time can be set)

6.Fault protection at over-current , over-voltage , under-voltage , over-temperature and overload with detailed fault information.

7.DC breaking , flux braking and resistor dynamic braking.

8.Over-current and over-voltage stall, stronger load adaptability

9.Can use the 380vac motor direct. Don’t need change the Voltage 380VAC motor is high Torque than 220VAC motor if same power 380VAC motor is cheaper than 220VAC motor.



For capacitance, our capacitance with heat shrink tube, it make our inverter not easy to short circuit.


About Us

We have 3 senior engineers in our R&D dept, we design and produce all kinds of voltage transformers regulators, stabilizers rector on the basis of our customers’ specific requirements.


Electronic products require a regular and appropriate maintenance schedule to operate reliably and economically over a long period of time. They need to have regular servicing and replacement of worn out parts. For all such maintenance we have a separate team which is specialized in scheduled and breakdown maintenance for our products. Our team is passionate about its business which positively reflects in our assertive approach to sales and customer service. 


Five layers corrugated board + industrial foam packaging, installation to reach your hands.


FAQ

Q: Do you have you own factory?

A: Yes! All of our products are supplied directly from our factory. Yueqing Winston Electrical Equipment Co.,Ltd who is professional manufacturing inverter, transformer and power switch etc for more then 10 years. So the price is very competitive. 

Q: Why choose us ?

A: 1. Famous brand in china for 10 more years ---- Winston 

2. Easy operating system ---- Easy but effective software, gentle touch achieves

3. Stable performance ---- best famous compenents ensure the quality all the time

4. Excellent aftersales service ---- 24*7 hours online serive, never leave you alone.

5. Fast delivery ---- cheap & safe delivery, we look after it all the time

Q: How do I choose the size of the inverter?

Different types of load demand for power are different. You can view the load power values to determine the size of the power inverter.


Hot Tags: 2500 watt power inverter, China, manufacturers, suppliers, factory, wholesale, customized, price, quotation, free sample, lc1d0910 ac contactor, Variable Frequency Inverter Drive, DC To AC Power Inverter, 0.75kw Frequency Inverter, one pole contactor, CJX2 Series contactor

Inquiry

You Might Also Like