380vAC Frequency Inverter

380vAC Frequency Inverter

Position control, speed control and torque control programmable
High quality IGBT
DC breaking, flux braking and resistor dynamic braking.
Chat Now

Product Details

WSTG600 Model Explanation

1

Product Description:

This 380vac frequency inverter can be widely used in various mechanical equipment control fields such as transmission, lifting, extrusion and machine tools. It can improve the process level and product quality, which helps reduce the impact and noise of the equipment. At the same time, it also extends the service life of the equipment. After adopting the 380vac frequency inverter, the mechanical system is simplified. What's more, the operation is more convenient in order to improve the function of the entire device.

Also, the frequency converter has many protection functions, such as overcurrent, overvoltage, overload protection, etc

 

Product Feature:

This 380vac frequency inverter is able to adjust the voltage and frequency of the output power supply easily. 

Our product helps to achieve the purpose of energy saving and speed regulation.

Equipped wit fast control function, it can be widely used for industrial automation, 

Our product can easily realize the fan to start at low frequency and reduce the wear between the belt and the bearing, which helps to extend the service life of the equipment.

 


Data Sheet

Three-phase power supply 380V 50/60Hz

Model

Power Capacity (kVA)

Input current

Output current

Adapation motor

KW

HP

WSTG600-4T0.7GB

1.5

3.4

2.1

0.75

1

WSTG600-4T1.5GB

3.0

5.0

3.8

1.5

2

WSTG600-4T2.2GB

4.0

5.8

5.1

2.2

3

WSTG600-4T4.0GB

5.9

10.5

9.0

4.0

5

WSTG600-4T5.5GB / WSTG600-4T5.5P-B

8.9

14.6

13.0

5.5

7.5

WSTG600-4T7.5GB / WSTG600-4T7.5P-B

11.0

20.5

17.0

7.5

10

WSTG600-4T11GB / WSTG600-4T11P-B

17.0

26.0

25.0

11.0

15

WSTG600-4T15GB / WSTG600-4T15P-B

21.0

35.0

32.0

15.0

20

WSTG600-4T18.5G / WSTG600-4T18.5P-B

24.0

38.5

37.0

18.5

25

WSTG600-4T22G / WSTG600-4T22P

30.0

46.5

45.0

22

30

WSTG600-4T30G / WSTG600-4T30P

40.0

62.0

60.0

30

40

WSTG600-4T37G / WSTG600-4T37P

57.0

76.0

75.0

37

50

WSTG600-4T45G / WSTG600-4T45P

69.0

92.0

91.0

45

60

WSTG600-4T55G / WSTG600-4T55P

85.0

113.0

112.0

55

70

WSTG600-4T75G / WSTG600-4T75P

114.0

157.0

150.0

75

100

WSTG600-4T90G / WSTG600-4T90P

134.0

180.0

176.0

90

125

WSTG600-4T110G / WSTG600-4T110P

160.0

214.0

210.0

110

150

WSTG600-4T132G / WSTG600-4T132P

192.0

256.0

253.0

132

175

WSTG600-4T160G / WSTG600-4T160P

231.0

307.0

304.0

160

210

WSTG600-4T185G / WSTG600-4T185P

234.0

326.0

350.0

185

250

WSTG600-4T200G / WSTG600-4T200P

250.0

385.0

377.0

200

260

WSTG600-4T220G / WSTG600-4T220P

280.0

430.0

426.0

220

300

WSTG600-4T250G / WSTG600-4T250P

355.0

468.0

465.0

250

350

WSTG600-4T280G / WSTG600-4T280P

396.0

525.0

520.0

280

370

WSTG600-4T315G / WSTG600-4T315P

445.0

590.0

585.0

315

500

WSTG600-4T355G / WSTG600-4T355P

500.0

665.0

650.0

355

420

WSTG600-4T400G / WSTG600-4T400P

565.0

785.0

725.0

400

530

WSTG600-4T450G

630.0

883.0

820.0

450

600


Basic Functions

Basic functions

Start frequency

0.00Hz~600.00Hz

Accel/Decel time

0.00s~60000s

Carrier frequency

0.5KHZ-16KHZ

Start methods

Start from starting frequency. DC injection braking at start; Flying start.

Stop methods

Ramp to stop. Coast to stop. DC injection braking at ramp stop.

Dynamic brake capability

Braking unit triggered voltage: 650-750V.Service time: 0.0s~100.0s.Brake units of G600-4T75 and below are optionally inbuilt.

DC braking capability

DC braking start frequency : 0.00Hz~600.00Hz. DC braking current: constart torque 0.0%~100.0%. DC braking time: 0.0s-100s.

Output terminals

One high-speed pulse output (0kHz~50kHz square wave output) and two analog outputs (voltage/current programmable), can output signals such as command frequency, output frequency etc. One digital output. One delay outputs.

Encode input terminals

Supports 5V/12V power supply. Support OC, push-pull, differential inputs and such.


Dimensions

2


Model

Mounting Holes(mm)

External dimension(mm)

Diameter (mm)

Weight (kg)

A

B

H

H1

W

D

Three phase power 380V

WSTG600-4T0.7GB

70

180

189

/

93

154

Φ5

1.1

WSTG600-4T1.5GB

WSTG600-4T2.2GB

WSTG600-4T4.0GB

80

233

245

/

120

173

Φ5

2.5

WSTG600-4T5.5P-B

WSTG600-4T5.5GB

125

268

281

/

145

185

Φ6

2.5

WSTG600-4T7.5P-B

WSTG600-4T7.5GB

WSTG600-4T11P-B

WSTG600-4T11GB

150

325

340

/

204

214

Φ6

6.5

WSTG600-4T15P-B

WSTG600-4T15G

WSTG600-4T18.5P-B

WSTG600-4T18.5G

150

380

400

/

228

217

Φ6

6.5

WSTG600-4T22P

WSTG600-4T22G

200

440

460

/

262

242

Φ8

20

WSTG600-4T30G

WSTG600-4T30P

WSTG600-4T37P

WSTG600-4T37G

235

528

550

/

320

253

Φ10

32

WSTG600-4T45P

WSTG600-4T45G

WSTG600-4T55P

WSTG600-4T55G

WSTG600-4T75P

WSTG600-4T75G

240

635

655

/

380

253

Φ10

47

WSTG600-4T90P

WSTG600-4T90G

WSTG600-4T110P

WSTG600-4T110G

WSTG600-4T132P

WSTG600-4T132G

400

760

790

/

586

317

Φ10

90

WSTG600-4T160P

WSTG600-4T160G

WSTG600-4T185P

WSTG600-4T185G

300

1090

1100

/

400

400

Φ10

122

WSTG600-4T200P

WSTG600-4T200G

WSTG600-4T220P

WSTG600-4T220G

560

1460

1600

/

500

420

Φ12

130

WSTG600-4T250P

WSTG600-4T250G

WSTG600-4T280P

WSTG600-4T280G

WSTG600-4T315P

WSTG600-4T315G

580

1160

1210

/

768

400

Φ14

200

WSTG600-4T355P

WSTG600-4T355G

WSTG600-4T400P

WSTG600-4T400G

WSTG600-4T450G


WSTG600 Single phase 220V inverter wiring diagram


WSTG600 Three phase 380V inverter wiring diagram


Device

Instructions

Power supply

Input three-phase AC power supply according to the user manual

Circuit breaker

Usage: When the post equipment over current, it will be cut the power supply and protect the post equipment.
Selection: The breaking current of the circuit breaker is 1.5-2 times of the rated current of the inverter; The time characteristic of circuit breaker needs to be selected according the inverter overload protection time characteristic.

Contactor

In order to ensure safety, please do not close and disconnect frequently which will cause inverter failure; Do not use the closed and disconnect the contactor on the system through the power of the inverter start and stop, which will reduce the life of the inverter

Braing unit and braking resistor

Use: When braking,it can effectively use the energy of the motor to achieve fast braking.
Selection: The selection of brake unit, please contact our technical staff directly, the braking resistor selection reference peripheral device selection table.

Output filter

Reduce the external conduction and radiation interference

Output AC reactor

It can effectively avoid the damage of the motor insulation due to the hidden wave voltage and reduce the frequency of the frequency converter. When the inverter to the motor connection over 100m, it is recommended to install the output AC reactor.

Motor

Selection of motor matched with frequency inverter





Incoming inspection, standardized use of turnover box standard packing bag.

Raw materials storage, strict control of quality, attention to detail, regulate the use of product turnover box, reduce static electricity.

8




We keep a large number of spot in warehouse, it could cut lead time of most items.


One years’ guarantee for free  from the date of delivery. Besides, any of the spare parts can be supplied, during the guarantee period and after the guarantee period.If you have any questions, please contact our customer service.




Hot Tags: 380vac frequency inverter, China, manufacturers, suppliers, factory, wholesale, customized, price, quotation, free sample, single phase motor contactor, 380v coil ac contactor, Fan Pump Inverter, cj20 ac contactor, 100 Hp Soft Starter, air conditioner contactor relay

Inquiry

You Might Also Like