WSTG600 Model Explanation
Data Sheet
Single phase power supply 220V 50/60Hz | |||||
Model | Power Capacity (kVA) | Input current | Output current | Adapation motor | |
KW | HP | ||||
WSTG600-2S0.4GB | 1.0 | 5.4 | 2.3 | 0.4 | 0.5 |
WSTG600-2S0.7GB | 1.5 | 8.2 | 4.0 | 0.75 | 1 |
WSTG600-2S1.5GB | 3.0 | 14.0 | 7.0 | 1.5 | 2 |
WSTG600-2S2.2GB | 4.0 | 23.0 | 9.6 | 2.2 | 3 |
WSTG600-2S4.0GB | 5.9 | 18 | 19.2 | 4 | 5 |
Three-phase power supply 380V 50/60Hz | |||||
Model | Power Capacity (kVA) | Input current | Output current | Adapation motor | |
KW | HP | ||||
WSTG600-4T0.7GB | 1.5 | 3.4 | 2.1 | 0.75 | 1 |
WSTG600-4T1.5GB | 3.0 | 5.0 | 3.8 | 1.5 | 2 |
WSTG600-4T2.2GB | 4.0 | 5.8 | 5.1 | 2.2 | 3 |
WSTG600-4T4.0GB | 5.9 | 10.5 | 9.0 | 4.0 | 5 |
WSTG600-4T5.5GB / WSTG600-4T5.5P-B | 8.9 | 14.6 | 13.0 | 5.5 | 7.5 |
WSTG600-4T7.5GB / WSTG600-4T7.5P-B | 11.0 | 20.5 | 17.0 | 7.5 | 10 |
WSTG600-4T11GB / WSTG600-4T11P-B | 17.0 | 26.0 | 25.0 | 11.0 | 15 |
WSTG600-4T15GB / WSTG600-4T15P-B | 21.0 | 35.0 | 32.0 | 15.0 | 20 |
WSTG600-4T18.5G / WSTG600-4T18.5P-B | 24.0 | 38.5 | 37.0 | 18.5 | 25 |
WSTG600-4T22G / WSTG600-4T22P | 30.0 | 46.5 | 45.0 | 22 | 30 |
WSTG600-4T30G / WSTG600-4T30P | 40.0 | 62.0 | 60.0 | 30 | 40 |
WSTG600-4T37G / WSTG600-4T37P | 57.0 | 76.0 | 75.0 | 37 | 50 |
WSTG600-4T45G / WSTG600-4T45P | 69.0 | 92.0 | 91.0 | 45 | 60 |
WSTG600-4T55G / WSTG600-4T55P | 85.0 | 113.0 | 112.0 | 55 | 70 |
WSTG600-4T75G / WSTG600-4T75P | 114.0 | 157.0 | 150.0 | 75 | 100 |
WSTG600-4T90G / WSTG600-4T90P | 134.0 | 180.0 | 176.0 | 90 | 125 |
WSTG600-4T110G / WSTG600-4T110P | 160.0 | 214.0 | 210.0 | 110 | 150 |
WSTG600-4T132G / WSTG600-4T132P | 192.0 | 256.0 | 253.0 | 132 | 175 |
WSTG600-4T160G / WSTG600-4T160P | 231.0 | 307.0 | 304.0 | 160 | 210 |
WSTG600-4T185G / WSTG600-4T185P | 234.0 | 326.0 | 350.0 | 185 | 250 |
WSTG600-4T200G / WSTG600-4T200P | 250.0 | 385.0 | 377.0 | 200 | 260 |
WSTG600-4T220G / WSTG600-4T220P | 280.0 | 430.0 | 426.0 | 220 | 300 |
WSTG600-4T250G / WSTG600-4T250P | 355.0 | 468.0 | 465.0 | 250 | 350 |
WSTG600-4T280G / WSTG600-4T280P | 396.0 | 525.0 | 520.0 | 280 | 370 |
WSTG600-4T315G / WSTG600-4T315P | 445.0 | 590.0 | 585.0 | 315 | 500 |
WSTG600-4T355G / WSTG600-4T355P | 500.0 | 665.0 | 650.0 | 355 | 420 |
WSTG600-4T400G / WSTG600-4T400P | 565.0 | 785.0 | 725.0 | 400 | 530 |
WSTG600-4T450G | 630.0 | 883.0 | 820.0 | 450 | 600 |
Dimensions
Model | Mounting Holes(mm) | External dimension(mm) | Diameter (mm) | Weight (kg) | ||||
A | B | H | H1 | W | D | |||
Single phase power 220V | ||||||||
WSTG600-2S0.4GB | 74 | 131 | 142 | / | 85 | 112.5 | Ф5 | 1.1 |
WSTG600-2S0.7GB | ||||||||
WSTG600-2S1.5GB | ||||||||
WSTG600-2S2.2GB | 70 | 180 | 189 | / | 93 | 154 | Φ5 | 1.1 |
WSTG600-2S4.0GB | 80 | 233 | 245 | / | 120 | 173 | Φ5 | 1.1 |
Three phase power 380V | ||||||||
WSTG600-4T0.7GB | 70 | 180 | 189 | / | 93 | 154 | Φ5 | 1.1 |
WSTG600-4T1.5GB | ||||||||
WSTG600-4T2.2GB | ||||||||
WSTG600-4T4.0GB | 80 | 233 | 245 | / | 120 | 173 | Φ5 | 2.5 |
WSTG600-4T5.5P-B | ||||||||
WSTG600-4T5.5GB | 125 | 268 | 281 | / | 145 | 185 | Φ6 | 2.5 |
WSTG600-4T7.5P-B | ||||||||
WSTG600-4T7.5GB | ||||||||
WSTG600-4T11P-B | ||||||||
WSTG600-4T11GB | 150 | 325 | 340 | / | 204 | 214 | Φ6 | 6.5 |
WSTG600-4T15P-B | ||||||||
WSTG600-4T15G | ||||||||
WSTG600-4T18.5P-B | ||||||||
WSTG600-4T18.5G | 150 | 380 | 400 | / | 228 | 217 | Φ6 | 6.5 |
WSTG600-4T22P | ||||||||
WSTG600-4T22G | 200 | 440 | 460 | / | 262 | 242 | Φ8 | 20 |
WSTG600-4T30G | ||||||||
WSTG600-4T30P | ||||||||
WSTG600-4T37P | ||||||||
WSTG600-4T37G | 235 | 528 | 550 | / | 320 | 253 | Φ10 | 32 |
WSTG600-4T45P | ||||||||
WSTG600-4T45G | ||||||||
WSTG600-4T55P | ||||||||
WSTG600-4T55G | ||||||||
WSTG600-4T75P | ||||||||
WSTG600-4T75G | 240 | 635 | 655 | / | 380 | 253 | Φ10 | 47 |
WSTG600-4T90P | ||||||||
WSTG600-4T90G | ||||||||
WSTG600-4T110P | ||||||||
WSTG600-4T110G | ||||||||
WSTG600-4T132P | ||||||||
WSTG600-4T132G | 400 | 760 | 790 | / | 586 | 317 | Φ10 | 90 |
WSTG600-4T160P | ||||||||
WSTG600-4T160G | ||||||||
WSTG600-4T185P | ||||||||
WSTG600-4T185G | 300 | 1090 | 1100 | / | 400 | 400 | Φ10 | 122 |
WSTG600-4T200P | ||||||||
WSTG600-4T200G | ||||||||
WSTG600-4T220P | ||||||||
WSTG600-4T220G | 560 | 1460 | 1600 | / | 500 | 420 | Φ12 | 130 |
WSTG600-4T250P | ||||||||
WSTG600-4T250G | ||||||||
WSTG600-4T280P | ||||||||
WSTG600-4T280G | ||||||||
WSTG600-4T315P | ||||||||
WSTG600-4T315G | 580 | 1160 | 1210 | / | 768 | 400 | Φ14 | 200 |
WSTG600-4T355P | ||||||||
WSTG600-4T355G | ||||||||
WSTG600-4T400P | ||||||||
WSTG600-4T400G | ||||||||
WSTG600-4T450G |
WSTG600 Single phase 220V inverter wiring diagram
WSTG600 Three phase 380V inverter wiring diagram
The situation frequency inverter need be equipped with filters:
1). When the disturbance to the frequency inverter is large, for example, the harmonic current is large, or the current is not clean, there is power generation or leakage backlash, it should be equipped with input filter or output filter.
2). Look at the use of occasions, such as high degree of automation, the use of PLC, touch screen, or computer screen control, this occasion will generally use filters, afraid of interfering with others.
3). Look at the usage environment,If the frequency inverter is used in computer room, there will be interference, and it will be equipped with input filter or output filter.
The situation frequency inverter need be equipped with reactor:
1). Voltage instability requires input reactor.
2). When the motor is far away from the frequency inverter, it will lead to signal failure. It needs output reactor to help boost the voltage.
PS: Input reactor and output reactor are not necessarily matched at the same time. But the standard is that both input and output can be matched.
Why Choose Us
Winston WSTG600 Series inverter, learned ABB internal structure design, we have moderate competitive price, it is very easy to operate and we often have stock, the delivery time is short. OEM is also acceptable.
Capacitor Brand: CECTN
Stock code: 833820
SHENZHEN CECTN TECHNOLOGY CO.,LTD specializes in the production of aluminum electrolytic capacitors for 25 years for industrial automation (frequency Inverter, servo, welder, uninterruptible power supply, medical equipment, communication power supply equipment, induction cooker, elevator, forklift, grid control, energy conversion equipment wind energy and solar power generation system Etc.), new energy (distribution cabinets, power companies and equipment management), railways (inverters, rail transportation, etc.), cars (hybrid, EPS, etc.) and other fields.
Unified wear static electricity wristband,Standardized production.
Staff uniform wear Static hand ring, static gloves to prevent the production of static electricity generated.
About Us
We are an ISO9001:2000 certified company. We have obtained many certificates, such as CCC, CE, CB, GS and RoHS. Stability, expertise and technological innovation are the core stones of our business strategy. Aiming at reliable product quality and the highest customer satisfaction, we are consistently deepening enterprise inner reform and fully carry out a quality guarantee system.
Mainly occupied the international market. Exported to Southeast Asia, Europe, North America, Australia, Middle East and other countries and regions, enjoy a high reputation in the world.
There is no perfect individual, only perfect team!Our company often organizes activities to enhance the cohesion and teamwork spirit of the company and further promote the corporate culture
FAQ:
Q: How to be Winston dealer in our country?
A: Winston Electrical are looking for a reliable dealer who have professional knowledge and good contacts in local market .and we will check his annual sales. As you know .the after sale service are very important. It need professional technician to do service. Most time it not quality problem. It may be application problem. How to set the parameters according to actual application.
Q: Why you should choose us?
---More than 10 years inverter experiences
---Professional team for both oversea and domestic market
---Qualified product plus competitable prices
---Delivery in time
---Sincerely services
Q: What’s the difference of line interactive UPS and Inverter?
A: Inverter has large capacity, can’t supply power immediately. Line interactive UPS has small capacity, can supply power immediately.