WSTG600 Model Explanation
Data Sheet
Single phase power supply 220V 50/60Hz | |||||
Model | Power Capacity (kVA) | Input current | Output current | Adapation motor | |
KW | HP | ||||
WSTG600-2S0.4GB | 1.0 | 5.4 | 2.3 | 0.4 | 0.5 |
WSTG600-2S0.7GB | 1.5 | 8.2 | 4.0 | 0.75 | 1 |
WSTG600-2S1.5GB | 3.0 | 14.0 | 7.0 | 1.5 | 2 |
WSTG600-2S2.2GB | 4.0 | 23.0 | 9.6 | 2.2 | 3 |
WSTG600-2S4.0GB | 5.9 | 18 | 19.2 | 4 | 5 |
Three-phase power supply 380V 50/60Hz | |||||
Model | Power Capacity (kVA) | Input current | Output current | Adapation motor | |
KW | HP | ||||
WSTG600-4T0.7GB | 1.5 | 3.4 | 2.1 | 0.75 | 1 |
WSTG600-4T1.5GB | 3.0 | 5.0 | 3.8 | 1.5 | 2 |
WSTG600-4T2.2GB | 4.0 | 5.8 | 5.1 | 2.2 | 3 |
WSTG600-4T4.0GB | 5.9 | 10.5 | 9.0 | 4.0 | 5 |
WSTG600-4T5.5GB / WSTG600-4T5.5P-B | 8.9 | 14.6 | 13.0 | 5.5 | 7.5 |
WSTG600-4T7.5GB / WSTG600-4T7.5P-B | 11.0 | 20.5 | 17.0 | 7.5 | 10 |
WSTG600-4T11GB / WSTG600-4T11P-B | 17.0 | 26.0 | 25.0 | 11.0 | 15 |
WSTG600-4T15GB / WSTG600-4T15P-B | 21.0 | 35.0 | 32.0 | 15.0 | 20 |
.... | .... | .... | .... | .... | .... |
Basic Functions
Dimensions
Model | Mounting Holes(mm) | External dimension(mm) | Diameter (mm) | Weight (kg) | ||||
A | B | H | H1 | W | D | |||
Single phase power 220V | ||||||||
WSTG600-2S0.4GB | 74 | 131 | 142 | / | 85 | 112.5 | Ф5 | 1.1 |
WSTG600-2S0.7GB | ||||||||
WSTG600-2S1.5GB | ||||||||
WSTG600-2S2.2GB | 70 | 180 | 189 | / | 93 | 154 | Φ5 | 1.1 |
WSTG600-2S4.0GB | 80 | 233 | 245 | / | 120 | 173 | Φ5 | 1.1 |
Three phase power 380V | ||||||||
WSTG600-4T0.7GB | 70 | 180 | 189 | / | 93 | 154 | Φ5 | 1.1 |
WSTG600-4T1.5GB | ||||||||
WSTG600-4T2.2GB | ||||||||
WSTG600-4T4.0GB | 80 | 233 | 245 | / | 120 | 173 | Φ5 | 2.5 |
WSTG600-4T5.5P-B | ||||||||
WSTG600-4T5.5GB | 125 | 268 | 281 | / | 145 | 185 | Φ6 | 2.5 |
WSTG600-4T7.5P-B | ||||||||
WSTG600-4T7.5GB | ||||||||
WSTG600-4T11P-B | ||||||||
WSTG600-4T11GB | 150 | 325 | 340 | / | 204 | 214 | Φ6 | 6.5 |
WSTG600-4T15P-B | ||||||||
WSTG600-4T15G | ||||||||
WSTG600-4T18.5P-B | ||||||||
WSTG600-4T18.5G | 150 | 380 | 400 | / | 228 | 217 | Φ6 | 6.5 |
WSTG600-4T22P |
WSTG600 Single phase 220V inverter wiring diagram
WSTG600 Three phase 380V inverter wiring diagram
Device | Instructions |
Power supply | Input three-phase AC power supply according to the user manual |
Circuit breaker | Usage: When the post equipment over current, it will be cut the power supply and protect the post equipment. |
Leakage protector | Usage: Because the inverter output is PWM high frequency chopping voltage,the high frequency current is inevitable. Selection: Recommended B type special leakage protector. |
Contactor | In order to ensure safety, please do not close and disconnect frequently which will cause inverter failure; Do not use the closed and disconnect the contactor on the system through the power of the inverter start and stop, which will reduce the life of the inverter |
Input AC reactor | Improve the efficiency factor; Improve the effect of unbalanced three-phase AC power supply on the system; Control the high order harmonics, reduce the interference of the external conduction and radiation, effectively reduce the pulse current on the rectifier bridge |
Input filter | Reducing the conduction interference from the power supply to the inverter; Improve the anti-interference ability of the frequency inverter; Reduce the external conduction and radiation interference. |
Braing unit and braking resistor | Use: When braking,it can effectively use the energy of the motor to achieve fast braking. |
Output filter | Reduce the external conduction and radiation interference |
Output AC reactor | It can effectively avoid the damage of the motor insulation due to the hidden wave voltage and reduce the frequency of the frequency converter. When the inverter to the motor connection over 100m, it is recommended to install the output AC reactor. |
Motor | Selection of motor matched with frequency inverter |
Why Choose Us
Standardize the production process, pay attention to detail.
Regulate the transfer of raw materials into the production process, Strictly control the quality of raw materials and quality.
Turnover of the next process, Regulate the use of turnover box.
Aging Test Room:Aging test for each inverter 12Hours
Our products are subjected to a 12-hour aging test before leaving the factory, dedicated to providing quality products to customers.
We can also Custom IP65, IP54 waterproof inverter, please send the specifications you need, our Technical team can customize for you, welcome to consult.
About Us
Applicatons:
Pump: 1.1kw, 2.2hp
Inverter: WSTG300-4T-2.2B
Panel: 200w mono panel,48pcs
Water flow and water head: 3t/h,75m
Highlights: Less noisy, less cost make it become popular
Mainly occupied the international market. Exported to Southeast Asia, Europe, North America, Australia, Middle East and other countries and regions ,enjoy a high reputation in the world.
The company's products have a wide range of applications.Including printing machinery, packaging machinery, winding machinery, film blowing machine, lathe, grinder, etc.Therefore, it is deeply loved by customers.
FAQ
Q: What is your terms of payment?
A: For small order, we require 100% payment in advance. For big order, we can also accept T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and packages before you pay the balance.
Q: What should be noticed when installing inverter?
A: Put the product in a place where is well ventilate, cool, dry and water-proof. Pls do not stress and do not put foreign objects into the inverter. Remember to turn on the inverter before turn on the appliance.
Q: Could I be your sale agent in our market?
A: It’s OK, we’ll depend on the sales turn over and also do research on your market.Let’s discuss more if you have interest.