32A 7.5 15kw Dol Starter Motor Magnetic Starter

32A 7.5 15kw Dol Starter Motor Magnetic Starter

LCD Display AC Power Motor Soft Starter 380V/415VAC 185kw (WSTR3185)
Chat Now

Product Details

We provide professional and personalized air conditioner contactor relay, 50 Hp Soft Start, lc1 d6511 ac contactor and solutions according to the different needs of customers. Our company continues to learn from the industry's advanced technology and introduce efficient equipment, our products are sold all over the world. Our company has built a business system that combines globalization and localization. We have always taken the quality of the product as the body for the survival of the company, the creative enthusiasm as the vitality of the company and the complete service as the engine of the company. Simple, efficient and fast product services will be provided for customers.

Model Of The Soft Starter

1


Data-sheet

Soft starter
230V/400V/660V-50/60Hz

Rated motor power

Model
appearance

Soft Starter
Model

Working Max
Allowable current

220V

380V

660V

Please refer to
The following page

WSTR3090

160

45KW

90KW

132KW

R2

WSTR3115

200

55KW

115KW

160KW

WSTR3132

250

75KW

132KW

200KW

WSTR3160

300

90KW

160KW

250KW

WSTR3200

360

115KW

200KW

355KW

WSTR3250

480

132KW

250KW

400KW

R3

WSTR3315

590

160KW

315KW

560KW

WSTR3355

660

/

355KW

630KW

WSTR3400

790

200KW

400KW

710KW

WSTR3500

1000

250KW

500KW

900KW

WSTR3630

1200

355KW

630KW

/


Basic Functions

Meet the standards

GB14048.6/IEC 60947-2-2:2002

Three phase power supply

AC 380V(optional 220V and 660V)

Frequency

50Hz/60Hz

Suitable motor

Squirrel cage three-phase asynchronous motor

Start-up frequency

When the motor is fully loaded, no more than 4 times per hour, no load or light load, no more than 10 times per hour.

Protection level

IP20

Anti shock

IEC68-2-27:15kg,11ms

Seismic capacity

At an altitude of 3000 below ground gas, the vibration stresses below 0.5G

Ambient temperature

working temperature

Storage temperature

-25

Ambient temperature

93% no condensation or drop

Maximum work

1000

Cooling mode

Natural cold wind

Relative to vertical

Vertical installation, angle range


External Dimensions

External dimensions of 90kw-400kw

Please see the below table for the external and installation dimensions of WSTR3000 series 90kw-400kwsoft starter.

1


Model

Rated power (KW)

Rated current(A)

External dimensions

Installation dimensions

Net weight
(kg)

H1

W1

D

H2

W2

d

WSTR 3090

90

180

400

270

240

355

244

M8

18

WSTR 3115

115

230

400

270

240

355

244

M8

18

WSTR 3132

132

264

400

270

240

355

244

M8

18

WSTR 3160

160

320

400

270

240

355

244

M8

18

WSTR 3200

200

400

400

270

240

355

244

M8

18

WSTR 3250

250

500

455

300

265

395

265

M8

28

WSTR 3280

280

560

455

300

265

395

265

M8

28

WSTR 3320

320

640

455

300

265

395

265

M8

28

WSTR 3400

400

800

455

300

265

395

265

M8

28


Connection Diagram For Main Circuit Of WSTR 3000 Soft Starter

3


Terminal Configuration Diagrams

Terminal diagram of the main circuit

1) WSTR3005-3075WSTR 3090-3400


2)Terminal diagram of the control circuit

3)Terminal connection of the control circuit


Why Choose Us

Description of protection functions

WSTR 3000 series soft starter possesses complete protection functions to protect the operation security of the soft starter and the motor. During operation, the protection level and protection parameters should be properly set base don different circumstances. 

● Over-heating protection of the soft starter: the protection will start when the temperature rises to 80℃±5℃, and it will stop when the temperature falls to 55℃(lowest). 

● Delayed time of input phase loss protection: <3s. 

● Delayed time of output phase loss protection: <3s.

● Delayed time of input three-phase unbalance protection: <3s. Taking the deviation of current in each phase is over 50%10% as the criteria, when the load current is less than 30% of the nominal rated value of the soft starter, it is confirmed that the deviation will increase. 

● Protection time of over-current during starting: the protection time shall be continued to be longer than 5 times of the maximum operating current of code F5, 

● Delayed time for power under-voltage protection: when the power voltage is under the extreme value 40%, the protection time< 0.5s, when the power voltage is below the set value, the protection time< 3s. 

● Delayed time for power over voltage protection: when the power voltage is over the extreme value 130%, the protection time< 0.5s, when the power voltage is over the set value, the protection time< 3s. 

● Delayed time for load short circuit protection < 0.1 s, if the current is more than IO times of the nominal rated value of the soft starter, this protection shall not replace the fuse or short circuit protection device. 

The above time parameters are the periods from the valid signal being detected to the tripping protection directive being given; these parameters are for information only. In the event that the protection functions of the soft starter fails to meet the requirements of customers, special protection devices should be installed to ensure the safety. 


Through the inbuilt RS485 standard interface, WSTR 3000 series soft starter can connect with PC and PLC and other hosts to conduct serial communication. The command of the host can control running or stop of the soft starter, monitor the running status of the soft starter and modify its functional data.      

Major functions 

1.Input of stop running command. 

2.Monitoring of the running status 

3.Real-time tracking (tabular display of the running information)

4.Read-once, write-once and saving to files of function codes. Please consult our company separately for the communication software. 

4


Starting Mode

Current limiting starting mode 

a)The soft starter will be under current starting mode when code F9 is set to O (current limiting). Figure shows the current change wave of the motor under the current limiting mode. 11 is the set starting current limiting value, when the motor starts, the output voltage will increase rapidly until the current of the motor reaches the set current limiting value 11, and the current of the motor will be kept under such value, then with the increasing of the output voltage, the motor will speed up gradually, and when the motor reaches the rated rotation speed, the bypass contact will close, the output current will drop rapidly to the rated current IE of the motor or less, and the whole starting process completes. 

b)When the load of the motor is relatively light or the set current limiting value is relatively high, it will be normal that the maximum current may not reach the set current limiting value. Generally, current limiting starting mode applies to the occasions where there're strict limiting requirements on starting current.

5


Voltage Ramp Starting

a)The soft starter will be under voltage starting mode when code F9 is set to I (voltage). Figure 12-2-1 shows the output voltage wave of the output ramp starting. UI is the starting voltage value at start, when the motor starts, if the current of the motor is within the range of the rated value 400%, the output voltage of the soft starter will increase to UI rapidly, then the starting parameter set according to the output voltage will rise gradually, and the motor will accelerate smoothly with the rising of the voltage and reach the rated rotation speed when the voltage reaches the rated voltage Ue, then the bypass contactor will close and the whole starting process completes.

b)Starting time: t is the control parameter calculated from the standard testing condition based on standard load. Taking this parameter as the criteria, thePRS 3000 series soft starter enables the motor accelerates smoothly through controlling the output voltage to complete the starting process. This parameter is not the mechanical control time t which has nothing to do with if the motor accelerates smoothly or not. Given this, when the load is relatively light, the starting time will be less than the set starting time, and it will be normal as long as the starting process completes smoothly. Generally, the voltage ramp starting mode applies to the occasions where high requirements are not placed in the starting current but in the starting smoothness. 

6


Kick Mode

a)The soft starter will be under kick starting mode when code F9 is set to 2(kick+ current limiting) or 3(kick + voltage). Figure 12-3-1 and 12-3-2 show the output change wave of the kick starting mode. In some occasions with heavy load, this starting mode can be used when the motor fails to be started due to effect of the mechanical static friction force. During start, apply a relatively high fixed voltage to the motor for a limited period to overcome the static friction force of the motor load to rotate the motor, then the motor will be started in the current limiting or fixed voltage ramp method.

b)Before using this mode, the motor shall be started through the non-kick mode, and this mode shall be only used when the motor fails to rotate due to high friction, otherwise, starting with this mode shall not be used to reduce the unnecessary shock caused by large current.

7


Current Ramp Starting Mode

a)The motor will be under current starting mode when code F9 is set to 4(current ramp). Figure 12-4-1 shows the output current wave of the current ramp starting mode, I 1 is the time value set by code F 1.

b)The current ramp starting mode possesses strong accelerating capacity, when used in bipolar motor, it can shorten the starting time to a certain extent.

8


About Us

● Yueqing Winston Electric Co., Ltd. is located in Wenzhou - the Electric Capital of China. We specialize in developing, manufacturing and distributing low voltage & high voltage electrical products. The products we professionally deal with are switching power supplies, sensors, relays, voltage stabilizers, AC contactors, circuit breakers, distribution boxes, industrial plugs & sockets and others. 


9


● Our company is not only an exporting company, but also a professional manufacturer in China. We have our own production base. So,we are sure that we can best support our customers with high quality products and the most competitive prices. 

10

● We have a Experienced Technicolor support team.Customer service in 1-4 hours. If there's any question, please contact us right now.

11

● Mainly occupied the international market. Exported to Southeast Asia, Europe, North America, Australia, Middle East and other countries and regions ,enjoy a high reputation in the world.

12

● If you need any help, please contact us immediately. And we would be very grateful if you have any comments. 

13


FAQ

Q: What’s delivery time?

A: It usually takes about 3-5 working days for small order and 10-15 days for big order.

Q: What’s your payment terms?

A: We usually accept all kinds of payment terms .Such as T/T,L/C, Western Union.PayPal,Cash.

Q: How to be Winston dealer in our country?

A: Winston Electrical are looking for a reliable dealer who have professional knowledge and good contacts in local market. and we will check his annual sales. As you know. the after sale service are very important. It need professional technician to do service. Most time it not quality problem. It may be application problem. How to set the parameters according to actual application.

Q: Do you have the products in stock?

A: Depends on your request, We have standard models in stock. Some special products and big order will be newly produced according to your order quantity.


We insist over the principle of enhancement of 'High high quality, Efficiency, Sincerity and Down-to-earth working approach' to offer you with superb assistance of processing for 32A 7.5 15kw Dol Starter Motor Magnetic Starter. We persist with the business philosophy of 'taking the market as the criterion, taking the innovative technology as the guide'. In the future development, we will maintain the spirit of 'gratefulness, integrity, innovation, and transcendence', actively exploring development ideas, increasing technological innovation, and improving quality management.
Hot Tags: magnetic motor starter, China, manufacturers, suppliers, factory, wholesale, customized, price, quotation, free sample, 2 pole contactor, Frequency Inverter For Fan, Vector Inverter, motor contactor, ac contactor 36v, 1.14kw vacuum contactor

Inquiry