Model Of The Soft Starter
Data-sheet
Soft starter |
Rated motor power |
Model |
|||
Soft Starter |
Working Max |
220V |
380V |
660V |
Please refer to |
WSTR3090 |
160 |
45KW |
90KW |
132KW |
R2 |
WSTR3115 |
200 |
55KW |
115KW |
160KW |
|
WSTR3132 |
250 |
75KW |
132KW |
200KW |
|
WSTR3160 |
300 |
90KW |
160KW |
250KW |
|
WSTR3200 |
360 |
115KW |
200KW |
355KW |
Basic Functions
Meet the standards |
GB14048.6/IEC 60947-2-2:2002 |
Three phase power supply |
AC 380V(optional 220V and 660V) |
Frequency |
50Hz/60Hz |
Suitable motor |
Squirrel cage three-phase asynchronous motor |
Start-up frequency |
When the motor is fully loaded, no more than 4 times per hour, no load or light load, no more than 10 times per hour. |
Protection level |
IP20 |
Anti shock |
IEC68-2-27:15kg,11ms |
Seismic capacity |
At an altitude of 3000 below ground gas, the vibration stresses below 0.5G |
Ambient temperature |
working temperature |
Storage temperature |
-25 |
Ambient temperature |
93% no condensation or drop |
Maximum work |
1000 |
Cooling mode |
Natural cold wind |
Relative to vertical |
Vertical installation, angle range |
External Dimensions
External dimensions of90kw-400kw
Please see the below table for the external and installation dimensions of WSTR3000 series 90kw-400kwsoft starter.
Model |
Rated power (KW) |
Rated current(A) |
External dimensions |
Installation dimensions |
Net weight |
||||
H1 |
W1 |
D |
H2 |
W2 |
d |
||||
WSTR 3090 |
90 |
180 |
400 |
270 |
240 |
355 |
244 |
M8 |
18 |
WSTR 3115 |
115 |
230 |
400 |
270 |
240 |
355 |
244 |
M8 |
18 |
WSTR 3132 |
132 |
264 |
400 |
270 |
240 |
355 |
244 |
M8 |
18 |
WSTR 3160 |
160 |
320 |
400 |
270 |
240 |
355 |
244 |
M8 |
18 |
WSTR 3200 |
200 |
400 |
400 |
270 |
240 |
355 |
244 |
M8 |
18 |
WSTR 3250 |
250 |
500 |
455 |
300 |
265 |
395 |
265 |
M8 |
28 |
WSTR 3280 |
280 |
560 |
455 |
300 |
265 |
395 |
265 |
M8 |
28 |
WSTR 3320 |
320 |
640 |
455 |
300 |
265 |
395 |
265 |
M8 |
28 |
WSTR 3400 |
400 |
800 |
455 |
300 |
265 |
395 |
265 |
M8 |
28 |
Connection Diagram For Main Circuit Of WSTR 3000 Soft Starter
Terminal configuration diagrams
Terminal diagram of the main circuit
1) WSTR3005-3075 | WSTR 3090-3400 |
2)Terminal diagram of the control circuit
3)Terminal connection of the control circuit
Why Choose Us
WSTR 3000 series soft starter possesses complete protection functions to protect the operation security of the soft starter and the motor. Here is Motor thermal protection tripping time curve based on IEC60947-4-2 standard is shown as follows:
Technical Characteristics
1.Unique SCR trigger closed-loop control algorithm
Unique SCR closed-loop control, specially designed for standard and heavy loads. The user can select the current limit start and the voltage ramp start according to the load condition to achieve an absolutely smooth torque-free oscillation start effect.
2.Control accuracy, real-time efficiency
High-performance CORETX-M3 32-bit core CPU for center control, fast speed, high precision, strong anti-interference ability
3.Beautiful appearance
Patented main circuit three-in and six-out structure, built-in current transformer scheme, convenient wiring and high reliability
4.Optional standard MODBUS-RTU protocol
Integrated advanced protection.It has protection functions such as input and output phase loss, overload, overcurrent, phase current imbalance, thyristor over temperature, etc., to protect the motor and related equipment in all directions.
5.Full refractory
90kw or less is a fully molded shell structure, processed with flame-retardant ABS material. The upper cover of 90KW and above is made of plastic shell structure, and the main frame is made of aluminum-zinc plate material. It has heat resistance and corrosion resistan
6.CE.
7.External lead panel
The panel can be externally led to the operating surface of the device for remote operation through the fuselage interface, which is convenient for on-site use.
8.Simple maintenance
A monitoring signal coding system consisting of a 4-digit digital display that monitors the operating conditions of system equipment 24 hours a day, while providing fast fault diagnosis
MODBUS Communication Protocol
Modbus is a kind of serial asynchronous communication protocol with RS485 as the physical interface. Being designed for Modicon PLC, it has the structural features of PLC. In network control, it can read and write the PRS 3000 as if it were a PLC. It can project the start and stop control, status information (current, fault etc.) and function parameters to the holding register (4:XXX). Its read and write control shall be conducted through the PL master station. When connected to other Modbus equipment, connection should be conducted as per the diagram below:
Description Of Protection Functions
WSTR 3000 series soft starter possesses complete protection functions to protect the operation security of the soft starter and the motor. During operation, the protection level and protection parameters should be properly set base don different circumstances.
● Over-heating protection of the soft starter: the protection will start when the temperature rises to 80℃±5℃, and it will stop when the temperature falls to 55℃(lowest).
● Delayed time of input phase loss protection: <3s.
● Delayed time of output phase loss protection: <3s.
● Delayed time of input three-phase unbalance protection: <3s. Taking the deviation of current in each phase is over 50%10% as the criteria, when the load current is less than 30% of the nominal rated value of the soft starter, it is confirmed that the deviation will increase.
● Protection time of over-current during starting: the protection time shall be continued to be longer than 5 times of the maximum operating current of code F5,
● Delayed time for power under-voltage protection: when the power voltage is under the extreme value 40%, the protection time< 0.5s, when the power voltage is below the set value, the protection time< 3s.
● Delayed time for power over voltage protection: when the power voltage is over the extreme value 130%, the protection time< 0.5s, when the power voltage is over the set value, the protection time< 3s.
● Delayed time for load short circuit protection < 0.1 s, if the current is more than IO times of the nominal rated value of the soft starter, this protection shall not replace the fuse or short circuit protection device.
The above time parameters are the periods from the valid signal being detected to the tripping protection directive being given; these parameters are for information only. In the event that the protection functions of the soft starter fails to meet the requirements of customers, special protection devices should be installed to ensure the safety.
About Us
● Yueqing Winston Electric Co., Ltd. is located in Wenzhou - the Electric Capital of China. We specialize in developing, manufacturing and distributing low voltage & high voltage electrical products. . The products we professionally deal with are switching power supplies, sensors, relays, voltage stabilizers, AC contactors, circuit breakers, distribution boxes, industrial plugs & sockets and others.
● With special cultivation of employees, high investment on production facilities and R&D as well as a wide range of products, we advocate "technology innovation, business honesty and trust and quality first" as our basic principle, trying to develop into a world-class electrical manufacturer with constant efforts.
● We have 3 senior engineers in our R&D dept, we design and produce all kinds of voltage transformers regulators, stabilizers rector on the basis of our customers’ specific requirements.
● Electronic products require a regular and appropriate maintenance schedule to operate reliably and economically over a long period of time. They need to have regular servicing and replacement of worn out parts. For all such maintenance we have a separate team which is specialized in scheduled and breakdown maintenance for our products. Our teamis passionate about its business which positively reflects in our assertive approach to sales and customer service.
● Mainly occupied the international market. Exported to Southeast Asia , Europe ,North America , Australia ,Middle East and other countries and regions ,enjoy a high reputation in the world.
FAQ
Q:What information should be provided to get a clear model with quotation?
A.Please directly provide input voltage, your requirements and usage occasion or our models.
Q:What's your quality control system?
A:We have strict quality control system, and each product is done fatigue testing, calibration, temperature compensation before shipment. High quality is guaranteed.
Q:How does your factory carry out quality control?
A:Quality is priority. Winston people always attaching great importance to quality controlling from the very beginning to the end. We have professional QC team to carry out the Quality control.
Q:How to choose a right system and products?
A:Leave it to us! Tell us your requirements, then our seller will recommend a suitable product and system to you.
Q:Why choose us?
A:Winston have been engaged in new energy power generation for more than 10 years. Our products and services cover more than 60 countries. Our R&D team is composed of top experts in various fields. We are committed to providing first-class solutions for PV power plants.