660v Starter Motor

660v Starter Motor

WSTRD3200 Built-in Bypass Motor 200kw Soft Starter for Industrial
Chat Now

Product Details

Model Of The Soft Starter

1


Data-sheet

Soft starter

230V/400V/660V-50/60Hz

Rated motor power

Model appearance

Soft Starter

Model

Working Max

Allowable current

220V

380V

660V

Please refer to

The following page

WSTR3007

15

4KW

7.5KW

11KW

R1

WSTR3011

23

5.5KW

11KW

15KW

WSTR3015

31

7.5KW

15KW

22KW

WSTR3018

38

9KW

18.5KW

30KW

WSTR3022

44

11KW

22KW

37KW

WSTR3030

60

15KW

30KW

45KW

WSTR3037

74

18.5KW

37KW

55KW

WSTR3045

100

22KW

45KW

75KW

WSTR3055

110

30KW

55KW

90KW

WSTR3075

150

37KW

75KW

115KW

WSTR3090

160

45KW

90KW

132KW

R2

WSTR3115

200

55KW

115KW

160KW

WSTR3132

250

75KW

132KW

200KW

WSTR3160

300

90KW

160KW

250KW

WSTR3200

360

115KW

200KW

355KW

WSTR3250

480

132KW

250KW

400KW

R3

WSTR3315

590

160KW

315KW

560KW

WSTR3355

660

/

355KW

630KW

WSTR3400

790

200KW

400KW

710KW

WSTR3500

1000

250KW

500KW

900KW

WSTR3630

1200

355KW

630KW

/


Basic Functions

1


External Dimensions

External dimensions of 5.5kw-75kw

Please see the below table for the external and installation dimensions of WS1R3000 series 5.5kw-75kw soft starter.

2


Model

Rated power (KW)

Rated current(A)

External dimensions

Installation dimensions

Net weight
(kg)

H1

W1

D

H2

W2

d

WSTR 3005

5.5

11

310

155

175

296

127

M6

5

WSTR 3007

7.5

15

310

155

176

296

127

M6

5

WSTR 3011

11

22

310

155

176

296

127

M6

5

WSTR 3013

15

30

310

155

176

296

127

M6

5

WSTR 3018

18.5

37

310

155

176

296

127

M6

5

WSTR 3022

22

43

310

155

176

296

127

M6

5

WSTR 3030

30

60

310

155

176

296

127

M6

5

WSTR 3037

37

75

310

155

176

296

127

M6

5

WSTR 3045

45

90

310

155

176

296

127

M6

5

WSTR 3055

55

110

310

155

176

296

127

M6

5

WSTR 3075

75

150

310

155

176

296

127

M6

5


External dimensions of 90kw-400kw

Please see the below table for the external and installation dimensions of WSTR3000 series 90kw-400kwsoft starter.

1


Model

Rated power (KW)

Rated current(A)

External dimensions

Installation dimensions

Net weight
(kg)

H1

W1

D

H2

W2

d

WSTR 3090

90

180

400

270

240

355

244

M8

18

WSTR 3115

115

230

400

270

240

355

244

M8

18

WSTR 3132

132

264

400

270

240

355

244

M8

18

WSTR 3160

160

320

400

270

240

355

244

M8

18

WSTR 3200

200

400

400

270

240

355

244

M8

18

WSTR 3250

250

500

455

300

265

395

265

M8

28

WSTR 3280

280

560

455

300

265

395

265

M8

28

WSTR 3320

320

640

455

300

265

395

265

M8

28

WSTR 3400

400

800

455

300

265

395

265

M8

28


Connection Diagram For Main Circuit Of WSTR 3000 Soft Starter

1


Terminal Configuration Diagrams

Terminal diagram of the main circuit

1) WSTR3005-3075WSTR 3090-3400


2)Terminal diagram of the control circuit

3)Terminal connection of the control circuit


Why Choose Us

WSTRD series Motor Starter has a Chinese & English LCD display to real-time display current, voltage and other operating status. The help information can be assessed when the soft starter is not in the soft start/ soft stop status or the setting status; press Yes(button for confirmation), then press the up/down buttons to read the prompt messages.


Display

Description

AC:XXX

Four-digit voltmeter, used to test the voltage of the three phase AC power

XXA-XXV

Indicate the specification of the soft starter

H1:Err0r00

Indicate that the latest fault information is zero

H2:Err0r00

Indicates no occurred fault information

H3:Err0r06

Indicates the occurred fault information Err0r06

...

...

H9:Err0r00

indicates no fault information

Ver:4.2

Indicates the software version of the product is Ver4. 2

LXXXX

The total times of successful starting

T-run

Time used in last soft start(whether succeed or not)

Note: HI-H9 saves the recent 9 fault information in the recursive method


MODBUS Communication Protocol

Modbus is a kind of serial asynchronous communication protocol with RS485 as the physical interface. Being designed for Modicon PLC, it has the structural features of PLC. In network control, it can read and write the PRS 3000 as if it were a PLC. It can project the start and stop control, status information (current, fault etc.) and function parameters to the holding register (4:XXX). Its read and write control shall be conducted through the PL master station. When connected to other Modbus equipment, connection should be conducted as per the diagram below:

1

 

Connection Of The Main Circuit And The Grounding Terminal

(I) Main circuit power input terminal (R,S, T) 

a.Connect the main circuit input terminals R, S, T to the three-phase AC power through the circuit breaker for circuit protection or circuit breaker with leakage protection without considering the connection sequence

b.Do not use ON/OFF of the main circuit power to control running and stop of the soft starter, instead, such should be controlled by means of the control terminal or RUN and STOP buttons in the keyboard panel of the soft starter upon power on. 

c.Do not connect the soft starter to the single-phase power. 

(2) Output terminals of the soft starter (U ,V ,W ) 

a.Output terminals of the soft starter should be connected to the three-phase motor in correct phase sequence. If the rotation direction of the motor is incorrect, switch connection of any two phases among U, V and W.

b.The output end of the soft starter shall not be connected to capacitor or surge absorber. 

c.If the wire between the soft starter and the motor is very long, the distributed capacitance between the wires will generate high­frequency current which may cause over-current tripping, leakage current increasing and poor current display precision of the soft starter. Therefore, it is suggested that the motor connection wire should be no more than 50m.

(3) Grounding terminal of the soft starter (〨 G)

a.For safety and noise reducing, the grounding terminal G of the soft starter must be well-grounded. To prevent electric shock and fire accidents, the metal enclosure and frame of the electric equipment should comply with the requirements of the national electronic procedures. 

2


● We are an ISO9001:2000 certified company. We have obtained many certificates, such as CCC, CE, CB, GS and RoHS. Stability, expertise and technological innovation are the core stones of our business strategy. Aiming at reliable product quality and the highest customer satisfaction, we are consistently deepening enterprise inner reform and fully carry out a quality guarantee system.

12


About Us

● Yueqing Winston Electric Co., Ltd. is located in Wenzhou - the Electric Capital of China. We specialize in developing, manufacturing and distributing low voltage & high voltage electrical products. The products we professionally deal with are switching power supplies, sensors, relays, voltage stabilizers,  AC contactors, circuit breakers, distribution boxes, industrial plugs & sockets and others. 


9


● With special cultivation of employees, high investment on production facilities and R&D as well as a wide range of products, we advocate "technology innovation, business honesty and trust and quality first" as our basic principle, trying to develop into a world-class electrical manufacturer with constant efforts. 

10

● We have 3 senior engineers in our R&D dept, we design and produce all kinds of voltage transformers regulators, stabilizers rector on the basis of our customers’ specific requirements. 

14

● We have customers from all of the world, and we hold exhibitions in different country.

20

● The company's products have a wide range of applications.Including printing machinery, packaging machinery, winding machinery, film blowing machine, lathe, grinder, etc.Therefore, it is deeply loved by customers.

25


FAQ

Q: Can you make the inverter and soft starter control A8:boards (control panel )?

A: Yes. We have a lot of experience to design VFD control panel and soft starter cabinet according to your request. It’s better for you to send us the primary wiring diagram.

Q: How to be Winston dealer in our country?

A: Winston Electrical are looking for a reliable dealer who have professional knowledge and good contacts in local market. and we will check his annual sales. As you know, the after sale service are very important. It need professional technician to do service. Most time it not quality problem. It may be application problem. How to set the parameters according to actual application.

Q: Do you have the products in stock?

A: Depends on your request, We have standard models in stock. Some special products and big order will be newly produced according to your order quantity.

Q: How does your factory do the quality control?

A: Quality is priority, we always attach the importance to quality control from the beginning to the end of the production. every product will be fully assembled and carefully tested before packing and shipping.

Q: Tell me the standard of package?

A: For the small capacity, it use carton, but for big capacity, we should use strong wooden case for protection.


Hot Tags: 660v starter motor, China, manufacturers, suppliers, factory, wholesale, customized, price, quotation, free sample, 3000 Watt Inverter, compressor contactor, 3 pole contactor, lc1 d115 ac contactor, lc1-d170 ac contactor, CJX2 Series contactor

Inquiry

You Might Also Like