Contactor Soft Starter

Contactor Soft Starter

Winston 220V 380V 30KW AC motor soft starter WSTR3030
Chat Now

Product Details

Model Of The Soft Starter

1


Data-sheet

Soft starter
230V/400V/660V-50/60Hz

Rated motor power

Model
appearance

Soft Starter
Model

Working Max
Allowable current

220V

380V

660V

Please refer to
The following page

WSTR3007

15

4KW

7.5KW

11KW

R1

WSTR3011

23

5.5KW

11KW

15KW

WSTR3015

31

7.5KW

15KW

22KW

WSTR3018

38

9KW

18.5KW

30KW

WSTR3022

44

11KW

22KW

37KW

WSTR3030

60

15KW

30KW

45KW

WSTR3037

74

18.5KW

37KW

55KW

WSTR3045

100

22KW

45KW

75KW

WSTR3055

110

30KW

55KW

90KW

WSTR3075

150

37KW

75KW

115KW


Basic Functions

Meet the standards

GB14048.6/IEC 60947-2-2:2002

Three phase power supply

AC 380V(optional 220V and 660V)

Frequency

50Hz/60Hz

Suitable motor

Squirrel cage three-phase asynchronous motor

Start-up frequency

When the motor is fully loaded, no more than 4 times per hour, no load or light load, no more than 10 times per hour.

Protection level

IP20

Anti shock

IEC68-2-27:15kg,11ms

Seismic capacity

At an altitude of 3000 below ground gas, the vibration stresses below 0.5G

Ambient temperature

working temperature

Storage temperature

-25

Ambient temperature

93% no condensation or drop

Maximum work

1000

Cooling mode

Natural cold wind

Relative to vertical

Vertical installation, angle range


External Dimensions

External dimensions of 5.5kw-75kw

Please see the below table for the external and installation dimensions ofWS1R3000 series 5.5kw-75kw soft starter. 

2


Model

Rated power (KW)

Rated current(A)

External dimensions

Installation dimensions

Net weight
(kg)

H1

W1

D

H2

W2

d

WSTR 3005

5.5

11

310

155

175

296

127

M6

5

WSTR 3007

7.5

15

310

155

176

296

127

M6

5

WSTR 3011

11

22

310

155

176

296

127

M6

5

WSTR 3013

15

30

310

155

176

296

127

M6

5

WSTR 3018

18.5

37

310

155

176

296

127

M6

5

WSTR 3022

22

43

310

155

176

296

127

M6

5

WSTR 3030

30

60

310

155

176

296

127

M6

5

WSTR 3037

37

75

310

155

176

296

127

M6

5

WSTR 3045

45

90

310

155

176

296

127

M6

5

WSTR 3055

55

110

310

155

176

296

127

M6

5

WSTR 3075

75

150

310

155

176

296

127

M6

5


Terminal Configuration Diagrams

Terminal diagram of the main circuit

1) WSTR3005-3075WSTR 3090-3400


2)Terminal diagram of the control circuit

3)Terminal connection of the control circuit


Why Choose Us

WSTRD series Motor Starter has a Chinese & English LCD display to real-time display current, voltage and other operating status. The help information can be assessed when the soft starter is not in the soft start/ soft stop status or the setting status; press Yes(button for confirmation), then press the up/down buttons to read the prompt messages. 


Display

Description

AC:XXX

Four-digit voltmeter, used to test the voltage of the three phase AC power

XXA-XXV

Indicate the specification of the soft starter

H1:Err0r00

Indicate that the latest fault information is zero

H2:Err0r00

Indicates no occurred fault information

H3:Err0r06

Indicates the occurred fault information Err0r06

...

...

H9:Err0r00

indicates no fault information

Ver:4.2

Indicates the software version of the product is Ver4. 2

LXXXX

The total times of successful starting

T-run

Time used in last soft start(whether succeed or not)

Note: HI-H9 saves the recent 9 fault information in the recursive method


Connection Of The Main Circuit And The Grounding Terminal

(I) Main circuit power input terminal (R,S, T) 

a.Connect the main circuit input terminals R, S, T to the three-phase AC power through the circuit breaker for circuit protection or circuit breaker with leakage protection without considering the connection sequence

b.Do not use ON/OFF of the main circuit power to control running and stop of the soft starter, instead, such should be controlled by means of the control terminal or RUN and STOP buttons in the keyboard panel of the soft starter upon power on. 

c.Do not connect the soft starter to the single-phase power. 

(2) Output terminals of the soft starter (U ,V ,W ) 

a.Output terminals of the soft starter should be connected to the three-phase motor in correct phase sequence. If the rotation direction of the motor is incorrect, switch connection of any two phases among U, V and W.

b.The output end of the soft starter shall not be connected to capacitor or surge absorber. 

c.If the wire between the soft starter and the motor is very long, the distributed capacitance between the wires will generate high­frequency current which may cause over-current tripping, leakage current increasing and poor current display precision of the soft starter. Therefore, it is suggested that the motor connection wire should be no more than 50m.

(3) Grounding terminal of the soft starter (〨 G)

a.For safety and noise reducing, the grounding terminal G of the soft starter must be well-grounded. To prevent electric shock and fire accidents, the metal enclosure and frame of the electric equipment should comply with the requirements of the national electronic procedures. 

4


Starting Mode

Current limiting starting mode 

a)The soft starter will be under current starting mode when code F9 is set to O (current limiting). Figure shows the current change wave of the motor under the current limiting mode. 11 is the set starting current limiting value, when the motor starts, the output voltage will increase rapidly until the current of the motor reaches the set current limiting value 11, and the current of the motor will be kept under such value, then with the increasing of the output voltage, the motor will speed up gradually, and when the motor reaches the rated rotation speed, the bypass contact will close, the output current will drop rapidly to the rated current IE of the motor or less, and the whole starting process completes. 

b)When the load of the motor is relatively light or the set current limiting value is relatively high, it will be normal that the maximum current may not reach the set current limiting value. Generally, current limiting starting mode applies to the occasions where there're strict limiting requirements on starting current.

5


Voltage Ramp Starting

a)The soft starter will be under voltage starting mode when code F9 is set to I (voltage). Figure 12-2-1 shows the output voltage wave of the output ramp starting. UI is the starting voltage value at start, when the motor starts, if the current of the motor is within the range of the rated value 400%, the output voltage of the soft starter will increase to UI rapidly, then the starting parameter set according to the output voltage will rise gradually, and the motor will accelerate smoothly with the rising of the voltage and reach the rated rotation speed when the voltage reaches the rated voltage Ue, then the bypass contactor will close and the whole starting process completes.

b)Starting time: t is the control parameter calculated from the standard testing condition based on standard load. Taking this parameter as the criteria, thePRS 3000 series soft starter enables the motor accelerates smoothly through controlling the output voltage to complete the starting process. This parameter is not the mechanical control time t which has nothing to do with if the motor accelerates smoothly or not. Given this, when the load is relatively light, the starting time will be less than the set starting time, and it will be normal as long as the starting process completes smoothly. Generally, the voltage ramp starting mode applies to the occasions where high requirements are not placed in the starting current but in the starting smoothness. 

6


Kick Mode

a)The soft starter will be under kick starting mode when code F9 is set to 2(kick+ current limiting) or 3(kick + voltage). Figure 12-3-1 and 12-3-2 show the output change wave of the kick starting mode. In some occasions with heavy load, this starting mode can be used when the motor fails to be started due to effect of the mechanical static friction force. During start, apply a relatively high fixed voltage to the motor for a limited period to overcome the static friction force of the motor load to rotate the motor, then the motor will be started in the current limiting or fixed voltage ramp method.

b)Before using this mode, the motor shall be started through the non-kick mode, and this mode shall be only used when the motor fails to rotate due to high friction, otherwise, starting with this mode shall not be used to reduce the unnecessary shock caused by large current.

7


Current Ramp Starting Mode

a)The motor will be under current starting mode when code F9 is set to 4(current ramp). Figure 12-4-1 shows the output current wave of the current ramp starting mode, I 1 is the time value set by code F 1.

b)The current ramp starting mode possesses strong accelerating capacity, when used in bipolar motor, it can shorten the starting time to a certain extent.

8


About Us

● Yueqing Winston Electric Co., Ltd.  is  located in Wenzhou - the Electric Capital of China. We specialize in developing, manufacturing and distributing low voltage & high voltage electrical products.  . The products we professionally deal with are switching power supplies, sensors, relays, voltage stabilizers,  AC contactors, circuit breakers, distribution boxes, industrial plugs & sockets and others. 

9


● With special cultivation of employees, high investment on production facilities and R&D as well as a wide range of products, we advocate "technology innovation, business honesty and trust and quality first" as our basic principle, trying to develop into a world-class electrical manufacturer with constant efforts. 

10

● According to the product external weight, the company has independent and suitable packaging for products.

11


● One years’ guarantee for free  from the date of delivery . Besides, any of the spare parts can be supplied , during the guarantee period and after the guarantee period.If you have any questions, please contact our customer service.


12


● We have customers from all of the world, and we hold exhibitions in different country.

 13


FAQ

Q: Could you print our company logo in nameplate and package?

A: Yes, we can do it according to your design. Please provide your logo file when place the order.

Q: Do you have any certificates ?

A: We have CE, Rohs, CCC, CQC, ISO9001:2015 Certification.

Q: What is your terms of packing?

A: Generally, we pack our goods in neutral boxes and brown cartons. If you have legally registered patent, we can pack the goods in your branded boxes after getting your authorization letters.

Q: What is your terms of payment?

A: For small order, we require 100% payment in advance. For big order, we can also accept T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and packages before you pay the balance.

Q: How do you make our business long-term and good relationship?

A:1). We keep good quality and competitive price to ensure our customers benefit ;

2). We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.


Hot Tags: contactor soft starter, China, manufacturers, suppliers, factory, wholesale, customized, price, quotation, free sample, 200kW AC Motor Controller, electrical magnetic contactor, ac contactor for panel, single phase magnetic ac contactor, cjx2 5011 ac contactor, 30kw Soft Starter

Inquiry

You Might Also Like