Built in Bypass Soft Starter

Built in Bypass Soft Starter

Winston 22KW 380V Motor Soft Drive Soft Starter built in bypass
Chat Now

Product Details

Model Of The Soft Starter

1


Data-sheet

Soft starter
230V/400V/660V-50/60Hz

Rated motor power

Model
appearance

Soft Starter
Model

Working Max
Allowable current

220V

380V

660V

Please refer to
The following page

WSTR3007

15

4KW

7.5KW

11KW

R1

WSTR3011

23

5.5KW

11KW

15KW

WSTR3015

31

7.5KW

15KW

22KW

WSTR3018

38

9KW

18.5KW

30KW

WSTR3022

44

11KW

22KW

37KW

WSTR3030

60

15KW

30KW

45KW

WSTR3037

74

18.5KW

37KW

55KW

WSTR3045

100

22KW

45KW

75KW

WSTR3055

110

30KW

55KW

90KW

WSTR3075

150

37KW

75KW

115KW


Basic Functions

Meet the standards

GB14048.6/IEC 60947-2-2:2002

Three phase power supply

AC 380V(optional 220V and 660V)

Frequency

50Hz/60Hz

Suitable motor

Squirrel cage three-phase asynchronous motor

Start-up frequency

When the motor is fully loaded, no more than 4 times per hour, no load or light load, no more than 10 times per hour.

Protection level

IP20

Anti shock

IEC68-2-27:15kg,11ms

Seismic capacity

At an altitude of 3000 below ground gas, the vibration stresses below 0.5G

Ambient temperature

working temperature

Storage temperature

-25

Ambient temperature

93% no condensation or drop

Maximum work

1000

Cooling mode

Natural cold wind

Relative to vertical

Vertical installation, angle range


External Dimensions

External dimensions of 5.5kw-75kw

Please see the below table for the external and installation dimensions of WS1R3000 series 5.5kw-75kw soft starter.

2


Model

Rated power (KW)

Rated current(A)

External dimensions

Installation dimensions

Net weight
(kg)

H1

W1

D

H2

W2

d

WSTR 3005

5.5

11

310

155

175

296

127

M6

5

WSTR 3007

7.5

15

310

155

176

296

127

M6

5

WSTR 3011

11

22

310

155

176

296

127

M6

5

WSTR 3013

15

30

310

155

176

296

127

M6

5

WSTR 3018

18.5

37

310

155

176

296

127

M6

5

WSTR 3022

22

43

310

155

176

296

127

M6

5

WSTR 3030

30

60

310

155

176

296

127

M6

5

WSTR 3037

37

75

310

155

176

296

127

M6

5

WSTR 3045

45

90

310

155

176

296

127

M6

5

WSTR 3055

55

110

310

155

176

296

127

M6

5

WSTR 3075

75

150

310

155

176

296

127

M6

5


Connection Diagram For Main Circuit Of WSTR 3000 Soft Starter

3


Terminal Configuration Diagrams

Terminal diagram of the main circuit

1) WSTR3005-3075WSTR 3090-3400


2)Terminal diagram of the control circuit

3)Terminal connection of the control circuit


Why Choose Us

Description Of Protection Functions

WSTR 3000 series soft starter possesses complete protection functions to protect the operation security of the soft starter and the motor. During operation, the protection level and protection parameters should be properly set base don different circumstances. 

● Over-heating protection of the soft starter: the protection will start when the temperature rises to 80℃±5℃, and it will stop when the temperature falls to 55℃(lowest). 

● Delayed time of input phase loss protection: <3s. 

● Delayed time of output phase loss protection: <3s.

● Delayed time of input three-phase unbalance protection: <3s. Taking the deviation of current in each phase is over 50%10% as the criteria, when the load current is less than 30% of the nominal rated value of the soft starter, it is confirmed that the deviation will increase. 

● Protection time of over-current during starting: the protection time shall be continued to be longer than 5 times of the maximum operating current of code F5, 

● Delayed time for power under-voltage protection: when the power voltage is under the extreme value 40%, the protection time< 0.5s, when the power voltage is below the set value, the protection time< 3s. 

● Delayed time for power over voltage protection: when the power voltage is over the extreme value 130%, the protection time< 0.5s, when the power voltage is over the set value, the protection time< 3s. 

● Delayed time for load short circuit protection < 0.1 s, if the current is more than IO times of the nominal rated value of the soft starter, this protection shall not replace the fuse or short circuit protection device. 

The above time parameters are the periods from the valid signal being detected to the tripping protection directive being given; these parameters are for information only. In the event that the protection functions of the soft starter fails to meet the requirements of customers, special protection devices should be installed to ensure the safety. 


Starting Mode

Current Limiting Starting Mode 

a)The soft starter will be under current starting mode when code F9 is set to O (current limiting). Figure shows the current change wave of the motor under the current limiting mode. 11 is the set starting current limiting value, when the motor starts, the output voltage will increase rapidly until the current of the motor reaches the set current limiting value 11, and the current of the motor will be kept under such value, then with the increasing of the output voltage, the motor will speed up gradually, and when the motor reaches the rated rotation speed, the bypass contact will close, the output current will drop rapidly to the rated current IE of the motor or less, and the whole starting process completes. 

b)When the load of the motor is relatively light or the set current limiting value is relatively high, it will be normal that the maximum current may not reach the set current limiting value. Generally, current limiting starting mode applies to the occasions where there're strict limiting requirements on starting current.

4


Soft Stop

There're two types of stop mode forWS1Rseries soft starter, namely, soft stop mode and free stop mode.

a) The soft starter will be under soft stop mode when code F2 is not set to 0. Figure 12-6-1 shows the output current wave of the soft stop mode.Tis the soft stop time set by the code F2. Under this stop mode, power supply of the motor will be switched to thyristor output of the soft starter through the bypass contactor, and the output voltage of the soft starter will gradually drop from the full voltage to enable the rotation speed of the motor reduce smoothly to avoid mechanical shock until the motor stops running. The output cut-off voltage during soft start shall be equal to the starting voltage during start.

b)The soft stop mode can reduce and even eliminate surge of load of pumps and reduce the large current shock during soft stop. The soft stop current limiting value is the percentage calculated from the starting current limiting. 

5


Free Stop

a) The soft starter will be under free stop mode when code F2 is set to O(free stop). Under this type of stop mode, upon receiving the command, the soft starter will disconnect the bypass contactor immediately and prohibit the voltage output of the thyristor of the soft starter, and then the motor will gradually stop due to load inertia. The code can be set to this mode when the soft starter is under the one-to-N connection method to avoid the phase loss fault alarm during output switching. 

b)Generally, in order to prolong the service life of the soft starter, free stop mode should be selected if there' s no necessary for soft stop. The free stop mode fully inhibits instantaneous output and thus it can prevent the instantaneous large current shock in the special application occasions. 

There are six different starting modes with the WS1R 3000 series soft starters which apply to various complicated motors and loading situations, among which users can select according to different application ranges.


Technical Characteristics

1.Unique SCR trigger closed-loop control algorithm

Unique SCR closed-loop control, specially designed for standard and heavy loads. The user can select the current limit start and the voltage ramp start according to the load condition to achieve an absolutely smooth torque-free oscillation start effect.

2.Control accuracy, real-time efficiency

High-performance CORETX-M3 32-bit core CPU for center control, fast speed, high precision, strong anti-interference ability

3.Beautiful appearance

Patented main circuit three-in and six-out structure, built-in current transformer scheme, convenient wiring and high reliability

4.Optional standard MODBUS-RTU protocol

Integrated advanced protection.It has protection functions such as input and output phase loss, overload, overcurrent, phase current imbalance, thyristor over temperature, etc., to protect the motor and related equipment in all directions.

5.Full refractory

90kw or less is a fully molded shell structure, processed with flame-retardant ABS material. The upper cover of 90KW and above is made of plastic shell structure, and the main frame is made of aluminum-zinc plate material. It has heat resistance and corrosion resistan

6.CE.

7.External lead panel

The panel can be externally led to the operating surface of the device for remote operation through the fuselage interface, which is convenient for on-site use.

8.Simple maintenance

A monitoring signal coding system consisting of a 4-digit digital display that monitors the operating conditions of system equipment 24 hours a day, while providing fast fault diagnosis.


About Us

● Yueqing Winston Electric Co., Ltd. is located in Wenzhou - the Electric Capital of China. We specialize in developing, manufacturing and distributing low voltage & high voltage electrical products. The products we professionally deal with are switching power supplies, sensors, relays, voltage stabilizers, AC contactors, circuit breakers, distribution boxes, industrial plugs & sockets and others. 


6


● Our company is not only an exporting company, but also a professional manufacturer in China. We have our own production base. So,we are sure that we can best support our customers with high quality products and the most competitive prices. 

7

● The company has a rigorous experimental team to develop and produce the latest and most practical products

8

● We have customers from all of the world, and we hold exhibitions in different country.

9

● There is no perfect individual, only perfect team!Our company often organizes activities to enhance the cohesion and teamwork spirit of the company and further promote the corporate culture

10


FAQ

Q: Can you accept to do OEM?

A: Yes, we accept OEM if you have a good quantity.

Q: Could you print our company logo in nameplate and package?

A: Yes, we can do it according to your design. Please provide your logo file when place the order.

Q: Do you have any certificates ?

A: We have CE, Rohs, CCC, CQC, ISO9001:2015 Certification.

Q: If I have a question I would like advice on how to contact you ?

A: You can send e-mail to consult us,and we will reply you in detail within 24 hours. Whatsapp, skype,wechat all ok.

Q: How to choose a right motor soft starter?

A: According to your requirement (like power, voltage and load), our sales will give you suitable suggestions. 


Hot Tags: built in bypass soft starter, China, manufacturers, suppliers, factory, wholesale, customized, price, quotation, free sample, Solar Power Inverter, Built In Bypass Soft Starter, 4 phase 63a ac contactor, Frequency Inverter, 2000 Watt Power Inverter, magnetic contactor switch